100 / 1000 Base -TX Single Port (1x1) Tab-Up Magnetic Module RJ45 Jack
Electrical Specifications:
|
|
1.Inductance :
|
350uH,MIN @100KHZ,0.1Vrms,8mA DC Bias
|
2.Turns Ratio :
|
P1-2:J1-1=1CT:1+/-3%
|
|
P3-6:J3-6=1CT:1+/-3%
|
3.Insertion Loss :
|
1~100MHZ -1.0dB MAX.
|
4.Return Loss :
|
1~10MHZ -20dB MIN .Load 100 OHMS
|
|
10~30MHZ -16dB MIN .Load 100 OHMS
|
|
30~60MHZ -12dB MIN .Load 100 OHMS
|
|
60~80MHZ -10dB MIN .Load 100 OHMS
|
5.Common Mode Rejection :
|
1~50 MHZ -30dB MIN
|
|
50~100MHZ -20dB MIN
|
6.Cross Talk :
|
1~100MHZ -30dBMIN
|
7.Hi-Pot Test :
|
1500Vrms 60sec. @PCB Side to Cable Side
|
Electrical Performance :
* Meets or exceeds IEEE 802.3 standard for 100Base-T.
* 350 uH minimum OCL with 8 mA bias current.
* High performance for maximum EMI suppression.
* Minimum 1500 Vrms isolation per IEEE 802.3 requirement.
* Operating temperature range: 0 0C to +70 0C.
* Storage temperature range: -40 0C to +85 0C.
Material Specifications :
* Insert: Plastic: Reinforced FR PA66-B30 UL94V-0.
* Contact Area: Phosphor Bronze, Gold Plated,6U~50U Optional.
* PCB Terminal: Phosphor Bronze, Tail-Tin over Nickel
* Housing: Reinforced FR PA66-B30 UL94V-0.
* Metal Shell: Copper Alloy, Nickel Plated
* Case: Phenolic, UL94V-0 Black..
Insertion Loss dB max |
Return Loss dB min | Crosstalk(dB TYP) | Common Mode Rejection (dB TYP) |
Hipot(Vrms) | |||||
1-100MHz | 1-30MHz | 30-60MHz | 60-80MHz | 1-30MHz | 30-60MHz | 60-80MHz | 1-50MHz | 50-150MHz | |
-1.0 | -18 | -16 | -12 | -40 | -35 | -30 | -30 | -20 | 1500 |
Part Number | Size | Speed | Schematic | LED | EMI Spring | Gold Plating |
BT50S(27-11)F4-03A-P213-B52 | 21.35*15.9*13.5 | 100M | F4-03A | G/Y | No | 6u" |
B50S(27-12)F4-239-P123-B52 | 21.35*15.9*13.5 | 100M | F4-239 | Y/G | Yes | 6u" |
B50S(27-16)F4-117-P223-B52 | 21.35*15.9*13.5 | 100M | F4-117 | G/Y | Yes | 6u" |
B50S(27-19)F4-03A-P223-B52 | 21.35*15.9*13.5 | 100M | F4-03A | G/Y | Yes | 6u" |
B50S(27-22)F4-03A-P213-B52 | 21.35*15.9*13.5 | 100M | F4-03A | G/Y | No | 6u" |
B50S(28-07)G8-85-P223-B52 | 21.35*15.9*13.5 | Gigabit | G8-85 | G/Y | Yes | 6u" |
B50S(28-09)G8-96-P023-B52 | 21.35*15.9*13.5 | Gigabit | G8-96 | None | Yes | 6u" |
B50S(28-16)G8-09-P623-B52 | 21.35*15.9*13.5 | Gigabit | G8-09 | GO/Y | Yes | 6u" |
B50S(28-20)G8-96-P323-B52 | 21.35*15.9*13.5 | Gigabit | G8-96 | G/G | Yes | 6u" |
B50S(28-21)G12-95-P626-B52 | 21.35*15.9*13.5 | Gigabit | G12-95 | GY/G | Yes | 50u" |
B50S(28-27)G8-140-P623-B52 | 21.35*15.9*13.5 | Gigabit | G8-140 | GO/Y | Yes | 6u" |
B50S(28-29)G12-95-P223-B52 | 21.35*15.9*13.5 | Gigabit | G12-95 | G/Y | Yes | 6u" |
B50S(28-31)G8-164-P223-B52 | 21.35*15.9*13.5 | Gigabit | G8-164 | G/Y | Yes | 6u" |
B50S(28-39)G8-174-P623-B52 | 21.35*15.9*13.5 | Gigabit | G8-174 | G/GY | Yes | 6u" |
B50S(28-40)PF6-258A-P223-B52 | 21.35*15.9*13.5 | 100M | PF6-258A | G/Y | Yes | 6u" |
B50S(28-42)G8-98-P223-B52 | 21.35*15.9*13.5 | Gigabit | G8-98 | G/Y | Yes | 6u" |
B50S(28-43)G8-09-P223-B52 | 21.35*15.9*13.5 | Gigabit | G8-09 | G/Y | Yes | 6u" |
B50S(28-45)G8-107-P123-B52 | 21.35*15.9*13.5 | Gigabit | G8-107 | Y/G | Yes | 6u" |
B50S(28-48)G8-208-P623-B52 | 21.35*15.9*13.5 | Gigabit | G8-208 | GO/Y | Yes | 6u" |
B50(29-01)F4-100-P213-B52 | 25.4*16.2*13.5 | 100M | F4-100 | G/Y | No | 6u" |
B50(29-02)F5-190-P213-B52 | 25.4*16.2*13.5 | 100M | F5-190 | G/Y | No | 6u" |
B50(29-03)F4-24-P213-B52 | 25.4*16.2*13.5 | 100M | F4-24 | G/Y | No | 6u" |
B50(29-06)FP4-198-P613-B52 | 25.4*16.2*13.5 | 100M | FP4-198 | GO/Y | No | 6u" |
B50(29-07)F4-24-P222-B12 | 25.4*16.2*13.5 | 100M | F4-24 | G/Y | Yes | 6u" |
B50(29-15)F4-100C-P214-B52 | 25.4*16.2*13.5 | 100M | F4-100C | G/Y | No | 15u" |
B50(29-18)F4-03B-P613-B52 | 25.4*16.2*13.5 | 100M | F4-03B | GR/GR | No | 6u" |
B50(29-30)F4-17-P223-B52 | 25.4*16.2*13.5 | 100M | F4-17 | G/Y | Yes | 6u" |
B50(29-33)F5-190-P213-B52 | 25.4*16.2*13.5 | 100M | F5-190 | G/Y | No | 6u" |
B50(29-31)F4-240-P223-B52 | 25.4*16.2*13.5 | 100M | F4-240 | G/Y | Yes | 6u" |
B50(29-35)F5-83-P213-B52 | 25.4*16.2*13.5 | 100M | F5-83 | G/Y | No | 6u" |
B50(29-36)F4-24A-P223-B92 | 25.4*16.2*13.5 | 100M | F4-24A | G/Y | Yes | 6u" |
B50(29-53)F4-263-P223-B52 | 25.4*16.2*13.5 | 100M | F4-263 | G/Y | Yes | 6u" |
B50(29-59)F4-100-P613-B92 | 25.4*16.2*13.5 | 100M | F4-100 | G/GY | No | 6u" |
B50(29-60)F4-24-P113-B52 | 25.4*16.2*13.5 | 100M | F4-24 | Y/G | No | 6u" |
B50(30-08)F4-262-P003-C52 | 25.4*16.2*13.5 | 100M | F4-262 | None | No | 6u" |
B50(31-02)F4-42A-P003-B52 | 25.4*16.2*13.5 | 100M | F4-42A | None | No | 6u" |
B50(36-06)F5-190-P013-B52 | 25.4*16.2*13.5 | 100M | F5-190 | None | No | 6u" |
B50(02-02)G8-87-P213-B52 | 25.4*16.2*13.5 | Gigabit | G8-87 | G/Y | No | 6u" |
B50(02-05)G8-27-P212-B52 | 25.4*16.2*13.5 | Gigabit | G8-27 | G/Y | No | 6u" |
B50(02-06)G8-86-P613-B52 | 25.4*16.2*13.5 | Gigabit | G8-86 | G/GO | No | 6u" |
B50(02-09)G8-86-P613-B52 | 25.4*16.2*13.5 | Gigabit | G8-86 | GO/Y | No | 6u" |
B50(02-10)G8-91-P613-B52 | 25.4*16.2*13.5 | Gigabit | G8-91 | GO/Y | No | 6u" |
B50(02-13)G8-09-P213-B52 | 25.4*16.2*13.5 | Gigabit | G8-09 | G/Y | No | 6u" |
B50(02-19)G8-91-P123-B52 | 25.4*16.2*13.5 | Gigabit | G8-91 | Y/G | Yes | 6u" |
B50(02-22)G8-91-P614-B52 | 25.4*16.2*13.5 | Gigabit | G8-91 | GO/Y | No | 15u" |
B50(02-23)G8-120-P223-B12 | 25.4*16.2*13.5 | Gigabit | G8-120 | G/Y | Yes | 6u" |
B50(02-26)G8-140-P623-B52 | 25.4*16.2*13.5 | Gigabit | G8-140 | GO/Y | Yes | 6u" |
B50(02-28)G8-140-P023-B52 | 25.4*16.2*13.5 | Gigabit | G8-140 | None | Yes | 6u" |
B50(02-29)G8-98-P223-B52 | 25.4*16.2*13.5 | Gigabit | G8-98 | G/Y | Yes | 6u" |
B50(02-30)G8-140-P623-B52 | 25.4*16.2*13.5 | Gigabit | G8-140 | GO/Y | Yes | 6u" |
B50(02-33)G8-197-P613-B92 | 25.4*16.2*13.5 | Gigabit | G8-197 | G | No | 6u" |
B50(02-36)G8-91-P623-B52 | 25.4*16.2*13.5 | Gigabit | G8-91 | GO/Y | Yes | 6u" |
B50(150-07)GP8-15-P622-F52 | 32.6*16.6*13.5 | Gigabit | GP8-15 | GO/Y | Yes | 6u" |
B50(150-22)G8-12-P322-F52 | 32.6*16.6*13.5 | Gigabit | G8-12 | G/G | Yes | 6u" |
B50(150-53)GP12-106-P623-F12 | 32.6*16.6*13.5 | Gigabit | GP12-106 | GO/Y | Yes | 6u" |
B50(150-57)G8-13-P623-F52 | 32.6*16.6*13.5 | Gigabit | G8-13 | GY/G | Yes | 6u" |
B50(150-58)GP8-15-P623-F12 | 32.6*16.6*13.5 | Gigabit | GP8-15 | GY/G | Yes | 6u" |
B50(150-60)G8-12-P623-F12 | 32.6*16.6*13.5 | Gigabit | G8-12 | GY/G | Yes | 6u" |
B50(150-68)GP8-15C-P023-F52 | 32.6*16.6*13.5 | Gigabit | GP8-15C | None | Yes | 6u" |
B50(150-72)G8-13-P323-F52 | 32.6*16.6*13.5 | Gigabit | G8-13 | G/G | Yes | 6u" |
B50(150-73)G8-12-P623-F52 | 32.6*16.6*13.5 | Gigabit | G8-12 | GO/Y | Yes | 6u" |
B50(150-85)GP8-15A-P113-F52 | 32.6*16.6*13.5 | Gigabit | GP8-15A | Y/G | No | 6u" |
B50(150-88)GP8-15-P623-F52 | 32.6*16.6*13.5 | Gigabit | GP8-15 | GY/GY | Yes | 6u" |
B50(150-90)GP8-218-P023-B52 | 32.6*16.6*13.5 | Gigabit | GP8-218 | None | Yes | 6u" |
B50(151-01)F4-27-P622-F12 | 32.6*16.6*13.5 | 100M | F4-27 | GY/Y | Yes | 6u" |
B50(151-02)FP4-150-P622-F12 | 32.6*16.6*13.5 | 100M | FP4-150 | G/GO | Yes | 6u" |
B50(151-03)FP4-150-P623-F12 | 32.6*16.6*13.5 | 100M | FP4-150 | GO/GO | Yes | 6u" |
B50(151-06)F4-243-P223-F52 | 32.6*16.6*13.5 | 100M | F4-243 | G/Y | Yes | 6u" |
B50(152-02)F4-27-P023-F52 | 32.6*16.6*13.5 | 100M | F4-27 | None | Yes | 6u" |
Electrical | Mechanical | ||
---|---|---|---|
Current rating: | 1 - 1.5A | Insertion force: | 2 contacts---350g |
Voltage rating: | 120 - 150V AC | 4 contacts---500g | |
Insulation resistance: | 500MΩ Min | 6 contacts---750g | |
Withstand voltage: | AC 1500Vrms 50Hz or 60Hz 1 Min | 8 contacts---900g | |
Contact resistance: | 20mΩ Max | 10 contacts---1050g | |
PoE rating: | 15W, 350mA, 84V (For PoE product only) | Retention strength: | 7.7Kg between jack and plug |
Durability: | 750 mating cycles mini | ||
Material | |||
Housing: | 1) glass filled PA66(ul 94v-0) | ||
2) glass filled PA46(ul 94v-0) | |||
3) glass filled PBT(ul 94v-0) | |||
Spring wire: | 1) 0.45mm dia phosphor bronze gold plating over nickel | ||
2) 0.35mm thickness phosphor bronze alloy | |||
selective gold plating over nickel | |||
Shielding: | 0.2mm thickness copper alloy with tin plated | ||
Gold plating: | 3μ″,6μ″,15μ″,30μ″,50μ″ | ||
Working temperature: | -20℃-70℃, -40℃-85℃ | ||
Relative humidity: | 70%±10% RH |
Persona de Contacto: cheng.yang
Gigabit industrial magnético 1 del grado del LED RJ45 Jack 2x4 - 1.5A con el transformador
Puerto dual RJ45 magnético Jack 1 - alto rendimiento 1.5A con el LED bicolor
Cuerpo largo RJ45 Jack con el Magnetics, zócalo del conector RJ45 para los usos del gigabit
Verde/el amarillo RJ45 llevó el conector, función apilada del PoE de los conectores RJ45
Entrada mínima vertical del POE RJ45 Jack 350µH OCLTop para el cable de Ethernet rápido
RJ45 conector modular femenino, función 120 del POE del conector del Lan RJ45 - CA 150V
Vertical magnética RJ45 Jack 10/100Mbps para CAT 5 y cable de Ethernet rápido 6
10/100 base-T RJ45 vertical Jack el solo puerto 8mA de 180 grados perjudica la corriente SIN EL LED
Función Cat6 RJ45 Jack del PoE para las tarjetas de interfaz de red y los usos de la PC
RJ45 LAN vertical Jack, RJ45 solo estándar del puerto IEEE802.3 para mejor UTP